Contexte

Le check Battery by SNMPv3 va vérifier l'état de fonctionnement de l'alimentation du serveur.


Paramétrage

Le check utilise la ligne de commande suivante :

$USERPLUGINSDIR$/shinken-additional-packs/iDRAC-by-API__shinken/check-idrac.py
	-H $_HOSTIDRAC_BY_SNMP__IP$ 
	-v 3 
	-l noAuthNoPriv 
	-u $_HOSTIDRAC_BY_SNMP__LOGIN$  
	-w BATTERY 
	-p 
	-m $_HOSTIDRAC_BY_SNMP__MIB$
$USERPLUGINSDIR$/shinken-additional-packs/iDRAC-by-API__shinken/check-idrac.py
	-H $_HOSTIDRAC_BY_SNMP__IP$ 
	-v 3 
	-l authNoPriv 
	-u $_HOSTIDRAC_BY_SNMP__LOGIN$ 
	-a $_HOSTIDRAC_BY_SNMP__AUTHPROTOCOL$ 
	-A $_HOSTIDRAC_BY_SNMP__AUTHPASSWORD$  
	-w BATTERY 
	-p 
	-m $_HOSTIDRAC_BY_SNMP__MIB$ 
$USERPLUGINSDIR$/shinken-additional-packs/iDRAC-by-API__shinken/check-idrac.py
	-H $_HOSTIDRAC_BY_SNMP__IP$ 
	-v 3 
	-l authPriv 
	-u $_HOSTIDRAC_BY_SNMP__LOGIN$ 
	-a $_HOSTIDRAC_BY_SNMP__AUTHPROTOCOL$ 
	-A $_HOSTIDRAC_BY_SNMP__AUTHPASSWORD$ 
	-x $_HOSTIDRAC_BY_SNMP__PRIVPROTOCOL$ 
	-X $_HOSTIDRAC_BY_SNMP__PRIVPASSWORD$  
	-w BATTERY 
	-p 
	-m $_HOSTIDRAC_BY_SNMP__MIB$

Données utilisées provenant des modèles

Données communes pour les checks des modèles

Données spécifiques pour ce check

Pas de données spécifiques pour ce check .

Données DFE ( Duplicate Foreach )

Pas de données DFE pour ce check .

Données utilisées provenant du check

Pas de données provenant du check pour ce modèle

Résultat

Exemple


Interprétation des données

Statut

  • Il peut prendre 4 valeurs  OK / CRITIQUE / INCONNU .

    • Le statut va dépendre du retour de sonde et de la configuration spécifique du check pour les données suivantes :

      • LINUX-BY-SNMP__DISKS-USAGE__STORAGE-WARN 
      • LINUX-BY-SNMP__DISKS-USAGE__STORAGE-CRIT
    • Voici un tableau récapitulatif du statut attendu suivant le retour de sonde :